Fuse Blowing On Furnace Control Board

Fuse Blowing On Furnace Control Board. The furnace has been serviced numerous times over the past two years for various problems by multiple service companies. One potential culprit for blown fuses is in the wiring.

5 Amp Control Board Fuse Keeps Blowing HELP! HVAC DIY
5 Amp Control Board Fuse Keeps Blowing HELP! HVAC DIY from www.diychatroom.com

After a while the a/c turned off. If the fuse blows when you have no low voltage wires hooked to the furnace then you have an internal problem like a bad limit, gas valve connection or control board. This will blow the fuse on the control board, causing the draft inducer to not start, which then stops the rest of the furnace functions from working properly.

With A Good Fuse In The Ac Work Fine And You Can Switch The Fan From Auto To Fan On With No Problem.


Short circuits or wire damage. I replaced the fuse and used the thermostat to turn the fan on followed by the heater then the a/c. We hope you are all enjoy and finally can find the best picture from our collection that put up here and also use for suited needs for personal use.

The Furnace Has Been Serviced Numerous Times Over The Past Two Years For Various Problems By Multiple Service Companies.


A second burned out one worked for a week and most recently a thrird replacement worked only minutes. While replacing a fuse in the system's panel or resetting the unit's breaker can be a temporary solution, the furnace will keep blowing fuses if the root cause isn't handled. Consequently, if the fuse has blown, it means you have a problem on hand for which you may require professional assistance.

I Would Check The Resistance (Ohms) Between The R And C Terminals On The T9 Thermostat With It Removed From Its Mounting Plate/Connector.


It isn't the hsi, inducer, or blower motor as these are all high voltage parts, not low voltage. If the fuse doesn't blow, turn the power off, then add one component back in at a time and repeat the procedure until you figure out which one is blowing the fuse. I replaced the fuse & rigged up a 2 foot thermostat cable to a thermostat controller and wired this to the board directly & made a call for heat & the new fuse blew again.

I Checked And The Furnace Was Off, Fuse Blown And Thermostat Was Asking For Cool.


The furnace requires a lot of electricity to run, and your home may not have the means to support it or there could be a short. On its own, the fuse cannot be a problem because it is just a part of the safety mechanism. Fuse in furnace circuit board keep blowing.

This Will Blow The Fuse On The Control Board, Causing The Draft Inducer To Not Start, Which Then Stops The Rest Of The Furnace Functions From Working Properly.


One potential culprit for blown fuses is in the wiring. Fan only operation is running fine 2. He just called and told me fuse is blown again.